www.pudn.com > myQTserial.rar > win_qextserialport.cpp


/*! 
\class Win_QextSerialPort 
\version 1.0.0 
\author Stefan Sander 
 
A cross-platform serial port class. 
This class encapsulates the Windows portion of QextSerialPort.  The user will be notified of 
errors and possible portability conflicts at run-time by default - this behavior can be turned 
off by defining _TTY_NOWARN_ (to turn off all warnings) or _TTY_NOWARN_PORT_ (to turn off 
portability warnings) in the project.  Note that defining _TTY_NOWARN_ also defines 
_TTY_NOWARN_PORT_. 
 
\note 
On Windows NT/2000/XP this class uses Win32 serial port functions by default.  The user may 
select POSIX behavior under NT, 2000, or XP ONLY by defining _TTY_POSIX_ in the project. I can 
make no guarantees as to the quality of POSIX support under NT/2000 however. 
 
*/ 
 
#include  
#include "win_qextserialport.h" 
 
/*! 
\fn Win_QextSerialPort::Win_QextSerialPort() 
Default constructor.  Note that the name of the device used by a Win_QextSerialPort constructed 
with this constructor will be determined by #defined constants, or lack thereof - the default 
behavior is the same as _TTY_LINUX_.  Possible naming conventions and their associated constants 
are: 
 
\verbatim 
 
Constant         Used By         Naming Convention 
----------       -------------   ------------------------ 
_TTY_WIN_        Windows         COM1, COM2 
_TTY_IRIX_       SGI/IRIX        /dev/ttyf1, /dev/ttyf2 
_TTY_HPUX_       HP-UX           /dev/tty1p0, /dev/tty2p0 
_TTY_SUN_        SunOS/Solaris   /dev/ttya, /dev/ttyb 
_TTY_DIGITAL_    Digital UNIX    /dev/tty01, /dev/tty02 
_TTY_FREEBSD_    FreeBSD         /dev/ttyd0, /dev/ttyd1 
_TTY_LINUX_      Linux           /dev/ttyS0, /dev/ttyS1 
           Linux           /dev/ttyS0, /dev/ttyS1 
\endverbatim 
 
This constructor associates the object with the first port on the system, e.g. COM1 for Windows 
platforms.  See the other constructor if you need a port other than the first. 
*/ 
Win_QextSerialPort::Win_QextSerialPort():QextSerialBase() { 
    Win_Handle=INVALID_HANDLE_VALUE; 
} 
 
/*!Win_QextSerialPort::Win_QextSerialPort(const Win_QextSerialPort&) 
Copy constructor. 
*/ 
Win_QextSerialPort::Win_QextSerialPort(const Win_QextSerialPort& s):QextSerialBase(s.port) { 
    Win_Handle=INVALID_HANDLE_VALUE; 
    portOpen=s.portOpen; 
    lastErr=s.lastErr; 
    port = s.port; 
    Settings.FlowControl=s.Settings.FlowControl; 
    Settings.Parity=s.Settings.Parity; 
    Settings.DataBits=s.Settings.DataBits; 
    Settings.StopBits=s.Settings.StopBits; 
    Settings.BaudRate=s.Settings.BaudRate; 
    Win_Handle=s.Win_Handle; 
    memcpy(&Win_CommConfig, &s.Win_CommConfig, sizeof(COMMCONFIG)); 
    memcpy(&Win_CommTimeouts, &s.Win_CommTimeouts, sizeof(COMMTIMEOUTS)); 
} 
 
/*! 
\fn Win_QextSerialPort::Win_QextSerialPort(const QString & name) 
Constructs a serial port attached to the port specified by devName. 
devName is the name of the device, which is windowsystem-specific, 
e.g."COM2" or "/dev/ttyS0". 
*/ 
Win_QextSerialPort::Win_QextSerialPort(const QString & name):QextSerialBase(name) { 
    Win_Handle=INVALID_HANDLE_VALUE; 
} 
 
/*! 
\fn Win_QextSerialPort::Win_QextSerialPort(const PortSettings& settings) 
Constructs a port with default name and specified settings. 
*/ 
Win_QextSerialPort::Win_QextSerialPort(const PortSettings& settings) { 
    Win_Handle=INVALID_HANDLE_VALUE; 
    setBaudRate(settings.BaudRate); 
    setDataBits(settings.DataBits); 
    setStopBits(settings.StopBits); 
    setParity(settings.Parity); 
    setFlowControl(settings.FlowControl); 
    setTimeout(settings.Timeout_Sec, settings.Timeout_Millisec); 
} 
 
/*! 
\fn Win_QextSerialPort::Win_QextSerialPort(const QString & name, const PortSettings& settings) 
Constructs a port with specified name and settings. 
*/ 
Win_QextSerialPort::Win_QextSerialPort(const QString & name, const PortSettings& settings) { 
    Win_Handle=INVALID_HANDLE_VALUE; 
    setPortName(name); 
    setBaudRate(settings.BaudRate); 
    setDataBits(settings.DataBits); 
    setStopBits(settings.StopBits); 
    setParity(settings.Parity); 
    setFlowControl(settings.FlowControl); 
    setTimeout(settings.Timeout_Sec, settings.Timeout_Millisec); 
} 
 
/*! 
\fn Win_QextSerialPort::~Win_QextSerialPort() 
Standard destructor. 
*/ 
Win_QextSerialPort::~Win_QextSerialPort() { 
    if (portOpen) { 
        close(); 
    } 
} 
 
/*! 
\fn Win_QextSerialPort& Win_QextSerialPort::operator=(const Win_QextSerialPort& s) 
overrides the = operator 
*/ 
Win_QextSerialPort& Win_QextSerialPort::operator=(const Win_QextSerialPort& s) { 
    portOpen=s.isOpen(); 
    lastErr=s.lastErr; 
    port = s.port; 
    Settings.FlowControl=s.Settings.FlowControl; 
    Settings.Parity=s.Settings.Parity; 
    Settings.DataBits=s.Settings.DataBits; 
    Settings.StopBits=s.Settings.StopBits; 
    Settings.BaudRate=s.Settings.BaudRate; 
    Win_Handle=s.Win_Handle; 
    memcpy(&Win_CommConfig, &s.Win_CommConfig, sizeof(COMMCONFIG)); 
    memcpy(&Win_CommTimeouts, &s.Win_CommTimeouts, sizeof(COMMTIMEOUTS)); 
    return *this; 
} 
 
/*! 
\fn bool Win_QextSerialPort::open(OpenMode) 
Opens a serial port.  Note that this function does not specify which device to open.  If you need 
to open a device by name, see Win_QextSerialPort::open(const char*).  This function has no effect 
if the port associated with the class is already open.  The port is also configured to the current 
settings, as stored in the Settings structure. 
*/ 
bool Win_QextSerialPort::open(OpenMode) { 
    unsigned long confSize; 
    LOCK_MUTEX(); 
    if (!portOpen) { 
 
        /*open the port*/ 
        Win_Handle=CreateFileA(port.toAscii(), GENERIC_READ|GENERIC_WRITE, 
                              FILE_SHARE_READ|FILE_SHARE_WRITE, NULL, OPEN_EXISTING, 0, NULL); 
        if (Win_Handle!=INVALID_HANDLE_VALUE) { 
            portOpen=true; 
 
            /*configure port settings*/ 
            GetCommConfig(Win_Handle, &Win_CommConfig, &confSize); 
            GetCommState(Win_Handle, &(Win_CommConfig.dcb)); 
 
            /*set up parameters*/ 
            Win_CommConfig.dcb.fBinary=TRUE; 
            Win_CommConfig.dcb.fInX=FALSE; 
            Win_CommConfig.dcb.fOutX=FALSE; 
            Win_CommConfig.dcb.fAbortOnError=FALSE; 
            Win_CommConfig.dcb.fNull=FALSE; 
            setBaudRate(Settings.BaudRate); 
            setDataBits(Settings.DataBits); 
            setStopBits(Settings.StopBits); 
            setParity(Settings.Parity); 
            setFlowControl(Settings.FlowControl); 
            setTimeout(Settings.Timeout_Sec, Settings.Timeout_Millisec); 
            SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
            setOpenMode(QIODevice::ReadWrite); 
        } 
    } 
    UNLOCK_MUTEX(); 
    return portOpen; 
} 
 
/*! 
\fn void Win_QextSerialPort::close() 
Closes a serial port.  This function has no effect if the serial port associated with the class 
is not currently open. 
*/ 
void Win_QextSerialPort::close() { 
    LOCK_MUTEX(); 
    CloseHandle(Win_Handle); 
    portOpen=false; 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::flush() 
Flushes all pending I/O to the serial port.  This function has no effect if the serial port 
associated with the class is not currently open. 
*/ 
void Win_QextSerialPort::flush() { 
    LOCK_MUTEX(); 
    if (portOpen) { 
        FlushFileBuffers(Win_Handle); 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn qint64 Win_QextSerialPort::size() const 
This function will return the number of bytes waiting in the receive queue of the serial port. 
It is included primarily to provide a complete QIODevice interface, and will not record errors 
in the lastErr member (because it is const).  This function is also not thread-safe - in 
multithreading situations, use Win_QextSerialPort::bytesAvailable() instead. 
*/ 
qint64 Win_QextSerialPort::size() const { 
    int availBytes; 
    COMSTAT Win_ComStat; 
    DWORD Win_ErrorMask=0; 
    ClearCommError(Win_Handle, &Win_ErrorMask, &Win_ComStat); 
    availBytes = Win_ComStat.cbInQue; 
    return (qint64)availBytes; 
} 
 
/*! 
\fn qint64 Win_QextSerialPort::bytesAvailable() 
Returns the number of bytes waiting in the port's receive queue.  This function will return 0 if 
the port is not currently open, or -1 on error.  Error information can be retrieved by calling 
Win_QextSerialPort::getLastError(). 
*/ 
qint64 Win_QextSerialPort::bytesAvailable() { 
    LOCK_MUTEX(); 
    if (portOpen) { 
        DWORD Errors; 
        COMSTAT Status; 
        bool success=ClearCommError(Win_Handle, &Errors, &Status); 
        translateError(Errors); 
        if (success) { 
            lastErr=E_NO_ERROR; 
            UNLOCK_MUTEX(); 
            return Status.cbInQue; 
        } 
        UNLOCK_MUTEX(); 
        return (unsigned int)-1; 
    } 
    UNLOCK_MUTEX(); 
    return 0; 
} 
 
/*! 
\fn void Win_QextSerialPort::translateError(ulong error) 
Translates a system-specific error code to a QextSerialPort error code.  Used internally. 
*/ 
void Win_QextSerialPort::translateError(ulong error) { 
    if (error&CE_BREAK) { 
        lastErr=E_BREAK_CONDITION; 
    } 
    else if (error&CE_FRAME) { 
        lastErr=E_FRAMING_ERROR; 
    } 
    else if (error&CE_IOE) { 
        lastErr=E_IO_ERROR; 
    } 
    else if (error&CE_MODE) { 
        lastErr=E_INVALID_FD; 
    } 
    else if (error&CE_OVERRUN) { 
        lastErr=E_BUFFER_OVERRUN; 
    } 
    else if (error&CE_RXPARITY) { 
        lastErr=E_RECEIVE_PARITY_ERROR; 
    } 
    else if (error&CE_RXOVER) { 
        lastErr=E_RECEIVE_OVERFLOW; 
    } 
    else if (error&CE_TXFULL) { 
        lastErr=E_TRANSMIT_OVERFLOW; 
    } 
} 
 
/*! 
\fn qint64 Win_QextSerialPort::readData(char *data, qint64 maxSize) 
Reads a block of data from the serial port.  This function will read at most maxlen bytes from 
the serial port and place them in the buffer pointed to by data.  Return value is the number of 
bytes actually read, or -1 on error.  This function will have no effect if the serial port 
associated with the class is not currently open. 
*/ 
qint64 Win_QextSerialPort::readData(char *data, qint64 maxSize) 
{ 
    LOCK_MUTEX(); 
    int retVal=0; 
    if (portOpen) { 
        COMSTAT Win_ComStat; 
        DWORD Win_BytesRead=0; 
        DWORD Win_ErrorMask=0; 
        ClearCommError(Win_Handle, &Win_ErrorMask, &Win_ComStat); 
        if (Win_ComStat.cbInQue && 
            (!ReadFile(Win_Handle, (void*)data, (DWORD)maxSize, &Win_BytesRead, NULL) 
            || Win_BytesRead==0)) { 
            lastErr=E_READ_FAILED; 
            retVal=-1; 
        } 
        else { 
            retVal=((int)Win_BytesRead); 
        } 
    } 
    UNLOCK_MUTEX(); 
    return retVal; 
} 
 
/*! 
\fn qint64 Win_QextSerialPort::writeData(const char *data, qint64 maxSize) 
Writes a block of data to the serial port.  This function will write len bytes 
from the buffer pointed to by data to the serial port.  Return value is the number 
of bytes actually written, or -1 on error.  This function will have no effect if the serial 
port associated with the class is not currently open. 
*/ 
qint64 Win_QextSerialPort::writeData(const char *data, qint64 maxSize) 
{ 
    LOCK_MUTEX(); 
    int retVal=0; 
    if (portOpen) { 
        DWORD Win_BytesWritten; 
        if (!WriteFile(Win_Handle, (void*)data, (DWORD)maxSize, &Win_BytesWritten, NULL)) { 
            lastErr=E_WRITE_FAILED; 
            retVal=-1; 
        } 
        else { 
            retVal=((int)Win_BytesWritten); 
        } 
    } 
    UNLOCK_MUTEX(); 
    flush(); 
    return retVal; 
} 
 
/*! 
\fn bool Win_QextSerialPort::getChar(char * c) 
Reads one character from the device and stores it in c. 
Returns true on success; otherwise returns false. 
This function has no effect if the serial port associated with the class is not currently open. 
*/ 
bool Win_QextSerialPort::getChar(char * c) { 
    LOCK_MUTEX(); 
    bool retVal=false; 
    if (portOpen) { 
        char readChar=0; 
        COMSTAT Win_ComStat; 
        DWORD Win_BytesRead=0; 
        DWORD Win_ErrorMask=0; 
        ClearCommError(Win_Handle, &Win_ErrorMask, &Win_ComStat); 
        if (Win_ComStat.cbInQue) { 
            if (!ReadFile(Win_Handle, (void*)&readChar, 1, &Win_BytesRead, NULL) 
                || Win_BytesRead==0) { 
                lastErr=E_READ_FAILED; 
            } 
            else { 
                *c = readChar; 
                retVal=true; 
            } 
        } 
    } 
    UNLOCK_MUTEX(); 
    return retVal; 
} 
 
/*! 
\fn bool Win_QextSerialPort::putChar(char c) 
Writes the character c to the device. Returns true on success; otherwise returns false. 
This function has no effect if the serial port associated with the class is not 
currently open. 
*/ 
bool Win_QextSerialPort::putChar(char c) { 
    LOCK_MUTEX(); 
    bool retVal=false; 
    if (portOpen) { 
        DWORD Win_BytesWritten; 
        if (!WriteFile(Win_Handle, (void*)&c, 1, &Win_BytesWritten, NULL)) { 
            lastErr=E_WRITE_FAILED; 
        } 
        else { 
            retVal=true; 
        } 
    } 
    UNLOCK_MUTEX(); 
    flush(); 
    return retVal; 
} 
 
/*! 
\fn void Win_QextSerialPort::ungetChar(char c) 
This function is included to implement the full QIODevice interface, and currently has no 
purpose within this class.  This function is meaningless on an unbuffered device and currently 
only prints a warning message to that effect. 
*/ 
void Win_QextSerialPort::ungetChar(char c) { 
 
    /*meaningless on unbuffered sequential device - return error and print a warning*/ 
    TTY_WARNING("Win_QextSerialPort: ungetChar() called on an unbuffered sequential device - operation is meaningless"); 
} 
 
/*! 
\fn void Win_QextSerialPort::setFlowControl(FlowType flow) 
Sets the flow control used by the port.  Possible values of flow are: 
\verbatim 
    FLOW_OFF            No flow control 
    FLOW_HARDWARE       Hardware (RTS/CTS) flow control 
    FLOW_XONXOFF        Software (XON/XOFF) flow control 
\endverbatim 
*/ 
void Win_QextSerialPort::setFlowControl(FlowType flow) { 
    LOCK_MUTEX(); 
    if (Settings.FlowControl!=flow) { 
        Settings.FlowControl=flow; 
    } 
    if (portOpen) { 
        switch(flow) { 
 
            /*no flow control*/ 
            case FLOW_OFF: 
                Win_CommConfig.dcb.fOutxCtsFlow=FALSE; 
                Win_CommConfig.dcb.fRtsControl=RTS_CONTROL_DISABLE; 
                Win_CommConfig.dcb.fInX=FALSE; 
                Win_CommConfig.dcb.fOutX=FALSE; 
                SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                break; 
 
            /*software (XON/XOFF) flow control*/ 
            case FLOW_XONXOFF: 
                Win_CommConfig.dcb.fOutxCtsFlow=FALSE; 
                Win_CommConfig.dcb.fRtsControl=RTS_CONTROL_DISABLE; 
                Win_CommConfig.dcb.fInX=TRUE; 
                Win_CommConfig.dcb.fOutX=TRUE; 
                SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                break; 
 
            case FLOW_HARDWARE: 
                Win_CommConfig.dcb.fOutxCtsFlow=TRUE; 
                Win_CommConfig.dcb.fRtsControl=RTS_CONTROL_HANDSHAKE; 
                Win_CommConfig.dcb.fInX=FALSE; 
                Win_CommConfig.dcb.fOutX=FALSE; 
                SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                break; 
        } 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::setParity(ParityType parity) 
Sets the parity associated with the serial port.  The possible values of parity are: 
\verbatim 
    PAR_SPACE       Space Parity 
    PAR_MARK        Mark Parity 
    PAR_NONE        No Parity 
    PAR_EVEN        Even Parity 
    PAR_ODD         Odd Parity 
\endverbatim 
*/ 
void Win_QextSerialPort::setParity(ParityType parity) { 
    LOCK_MUTEX(); 
    if (Settings.Parity!=parity) { 
        Settings.Parity=parity; 
    } 
    if (portOpen) { 
        Win_CommConfig.dcb.Parity=(unsigned char)parity; 
        switch (parity) { 
 
            /*space parity*/ 
            case PAR_SPACE: 
                if (Settings.DataBits==DATA_8) { 
                    TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning: Space parity with 8 data bits is not supported by POSIX systems."); 
                } 
                Win_CommConfig.dcb.fParity=TRUE; 
                break; 
 
            /*mark parity - WINDOWS ONLY*/ 
            case PAR_MARK: 
                TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning:  Mark parity is not supported by POSIX systems"); 
                Win_CommConfig.dcb.fParity=TRUE; 
                break; 
 
            /*no parity*/ 
            case PAR_NONE: 
                Win_CommConfig.dcb.fParity=FALSE; 
                break; 
 
            /*even parity*/ 
            case PAR_EVEN: 
                Win_CommConfig.dcb.fParity=TRUE; 
                break; 
 
            /*odd parity*/ 
            case PAR_ODD: 
                Win_CommConfig.dcb.fParity=TRUE; 
                break; 
        } 
        SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::setDataBits(DataBitsType dataBits) 
Sets the number of data bits used by the serial port.  Possible values of dataBits are: 
\verbatim 
    DATA_5      5 data bits 
    DATA_6      6 data bits 
    DATA_7      7 data bits 
    DATA_8      8 data bits 
\endverbatim 
 
\note 
This function is subject to the following restrictions: 
\par 
    5 data bits cannot be used with 2 stop bits. 
\par 
    1.5 stop bits can only be used with 5 data bits. 
\par 
    8 data bits cannot be used with space parity on POSIX systems. 
 
*/ 
void Win_QextSerialPort::setDataBits(DataBitsType dataBits) { 
    LOCK_MUTEX(); 
    if (Settings.DataBits!=dataBits) { 
        if ((Settings.StopBits==STOP_2 && dataBits==DATA_5) || 
            (Settings.StopBits==STOP_1_5 && dataBits!=DATA_5)) { 
        } 
        else { 
            Settings.DataBits=dataBits; 
        } 
    } 
    if (portOpen) { 
        switch(dataBits) { 
 
            /*5 data bits*/ 
            case DATA_5: 
                if (Settings.StopBits==STOP_2) { 
                    TTY_WARNING("Win_QextSerialPort: 5 Data bits cannot be used with 2 stop bits."); 
                } 
                else { 
                    Win_CommConfig.dcb.ByteSize=5; 
                    SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                } 
                break; 
 
            /*6 data bits*/ 
            case DATA_6: 
                if (Settings.StopBits==STOP_1_5) { 
                    TTY_WARNING("Win_QextSerialPort: 6 Data bits cannot be used with 1.5 stop bits."); 
                } 
                else { 
                    Win_CommConfig.dcb.ByteSize=6; 
                    SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                } 
                break; 
 
            /*7 data bits*/ 
            case DATA_7: 
                if (Settings.StopBits==STOP_1_5) { 
                    TTY_WARNING("Win_QextSerialPort: 7 Data bits cannot be used with 1.5 stop bits."); 
                } 
                else { 
                    Win_CommConfig.dcb.ByteSize=7; 
                    SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                } 
                break; 
 
            /*8 data bits*/ 
            case DATA_8: 
                if (Settings.StopBits==STOP_1_5) { 
                    TTY_WARNING("Win_QextSerialPort: 8 Data bits cannot be used with 1.5 stop bits."); 
                } 
                else { 
                    Win_CommConfig.dcb.ByteSize=8; 
                    SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                } 
                break; 
        } 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::setStopBits(StopBitsType stopBits) 
Sets the number of stop bits used by the serial port.  Possible values of stopBits are: 
\verbatim 
    STOP_1      1 stop bit 
    STOP_1_5    1.5 stop bits 
    STOP_2      2 stop bits 
\endverbatim 
 
\note 
This function is subject to the following restrictions: 
\par 
    2 stop bits cannot be used with 5 data bits. 
\par 
    1.5 stop bits cannot be used with 6 or more data bits. 
\par 
    POSIX does not support 1.5 stop bits. 
*/ 
void Win_QextSerialPort::setStopBits(StopBitsType stopBits) { 
    LOCK_MUTEX(); 
    if (Settings.StopBits!=stopBits) { 
        if ((Settings.DataBits==DATA_5 && stopBits==STOP_2) || 
            (stopBits==STOP_1_5 && Settings.DataBits!=DATA_5)) { 
        } 
        else { 
            Settings.StopBits=stopBits; 
        } 
    } 
    if (portOpen) { 
        switch (stopBits) { 
 
            /*one stop bit*/ 
            case STOP_1: 
                Win_CommConfig.dcb.StopBits=ONESTOPBIT; 
                SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                break; 
 
            /*1.5 stop bits*/ 
            case STOP_1_5: 
                TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning: 1.5 stop bit operation is not supported by POSIX."); 
                if (Settings.DataBits!=DATA_5) { 
                    TTY_WARNING("Win_QextSerialPort: 1.5 stop bits can only be used with 5 data bits"); 
                } 
                else { 
                    Win_CommConfig.dcb.StopBits=ONE5STOPBITS; 
                    SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                } 
                break; 
 
            /*two stop bits*/ 
            case STOP_2: 
                if (Settings.DataBits==DATA_5) { 
                    TTY_WARNING("Win_QextSerialPort: 2 stop bits cannot be used with 5 data bits"); 
                } 
                else { 
                    Win_CommConfig.dcb.StopBits=TWOSTOPBITS; 
                    SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
                } 
                break; 
        } 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::setBaudRate(BaudRateType baudRate) 
Sets the baud rate of the serial port.  Note that not all rates are applicable on 
all platforms.  The following table shows translations of the various baud rate 
constants on Windows(including NT/2000) and POSIX platforms.  Speeds marked with an * 
are speeds that are usable on both Windows and POSIX. 
\verbatim 
 
  RATE          Windows Speed   POSIX Speed 
  -----------   -------------   ----------- 
   BAUD50                 110          50 
   BAUD75                 110          75 
  *BAUD110                110         110 
   BAUD134                110         134.5 
   BAUD150                110         150 
   BAUD200                110         200 
  *BAUD300                300         300 
  *BAUD600                600         600 
  *BAUD1200              1200        1200 
   BAUD1800              1200        1800 
  *BAUD2400              2400        2400 
  *BAUD4800              4800        4800 
  *BAUD9600              9600        9600 
   BAUD14400            14400        9600 
  *BAUD19200            19200       19200 
  *BAUD38400            38400       38400 
   BAUD56000            56000       38400 
  *BAUD57600            57600       57600 
   BAUD76800            57600       76800 
  *BAUD115200          115200      115200 
   BAUD128000          128000      115200 
   BAUD256000          256000      115200 
\endverbatim 
*/ 
void Win_QextSerialPort::setBaudRate(BaudRateType baudRate) { 
    LOCK_MUTEX(); 
    if (Settings.BaudRate!=baudRate) { 
        switch (baudRate) { 
            case BAUD50: 
            case BAUD75: 
            case BAUD134: 
            case BAUD150: 
            case BAUD200: 
                Settings.BaudRate=BAUD110; 
                break; 
 
            case BAUD1800: 
                Settings.BaudRate=BAUD1200; 
                break; 
 
            case BAUD76800: 
                Settings.BaudRate=BAUD57600; 
                break; 
 
            default: 
                Settings.BaudRate=baudRate; 
                break; 
        } 
    } 
    if (portOpen) { 
        switch (baudRate) { 
 
            /*50 baud*/ 
            case BAUD50: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 50 baud operation.  Switching to 110 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_110; 
                break; 
 
            /*75 baud*/ 
            case BAUD75: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 75 baud operation.  Switching to 110 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_110; 
                break; 
 
            /*110 baud*/ 
            case BAUD110: 
                Win_CommConfig.dcb.BaudRate=CBR_110; 
                break; 
 
            /*134.5 baud*/ 
            case BAUD134: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 134.5 baud operation.  Switching to 110 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_110; 
                break; 
 
            /*150 baud*/ 
            case BAUD150: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 150 baud operation.  Switching to 110 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_110; 
                break; 
 
            /*200 baud*/ 
            case BAUD200: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 200 baud operation.  Switching to 110 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_110; 
                break; 
 
            /*300 baud*/ 
            case BAUD300: 
                Win_CommConfig.dcb.BaudRate=CBR_300; 
                break; 
 
            /*600 baud*/ 
            case BAUD600: 
                Win_CommConfig.dcb.BaudRate=CBR_600; 
                break; 
 
            /*1200 baud*/ 
            case BAUD1200: 
                Win_CommConfig.dcb.BaudRate=CBR_1200; 
                break; 
 
            /*1800 baud*/ 
            case BAUD1800: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 1800 baud operation.  Switching to 1200 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_1200; 
                break; 
 
            /*2400 baud*/ 
            case BAUD2400: 
                Win_CommConfig.dcb.BaudRate=CBR_2400; 
                break; 
 
            /*4800 baud*/ 
            case BAUD4800: 
                Win_CommConfig.dcb.BaudRate=CBR_4800; 
                break; 
 
            /*9600 baud*/ 
            case BAUD9600: 
                Win_CommConfig.dcb.BaudRate=CBR_9600; 
                break; 
 
            /*14400 baud*/ 
            case BAUD14400: 
                TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning: POSIX does not support 14400 baud operation."); 
                Win_CommConfig.dcb.BaudRate=CBR_14400; 
                break; 
 
            /*19200 baud*/ 
            case BAUD19200: 
                Win_CommConfig.dcb.BaudRate=CBR_19200; 
                break; 
 
            /*38400 baud*/ 
            case BAUD38400: 
                Win_CommConfig.dcb.BaudRate=CBR_38400; 
                break; 
 
            /*56000 baud*/ 
            case BAUD56000: 
                TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning: POSIX does not support 56000 baud operation."); 
                Win_CommConfig.dcb.BaudRate=CBR_56000; 
                break; 
 
            /*57600 baud*/ 
            case BAUD57600: 
                Win_CommConfig.dcb.BaudRate=CBR_57600; 
                break; 
 
            /*76800 baud*/ 
            case BAUD76800: 
                TTY_WARNING("Win_QextSerialPort: Windows does not support 76800 baud operation.  Switching to 57600 baud."); 
                Win_CommConfig.dcb.BaudRate=CBR_57600; 
                break; 
 
            /*115200 baud*/ 
            case BAUD115200: 
                Win_CommConfig.dcb.BaudRate=CBR_115200; 
                break; 
 
            /*128000 baud*/ 
            case BAUD128000: 
                TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning: POSIX does not support 128000 baud operation."); 
                Win_CommConfig.dcb.BaudRate=CBR_128000; 
                break; 
 
            /*256000 baud*/ 
            case BAUD256000: 
                TTY_PORTABILITY_WARNING("Win_QextSerialPort Portability Warning: POSIX does not support 256000 baud operation."); 
                Win_CommConfig.dcb.BaudRate=CBR_256000; 
                break; 
        } 
        SetCommConfig(Win_Handle, &Win_CommConfig, sizeof(COMMCONFIG)); 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::setDtr(bool set) 
Sets DTR line to the requested state (high by default).  This function will have no effect if 
the port associated with the class is not currently open. 
*/ 
void Win_QextSerialPort::setDtr(bool set) { 
    LOCK_MUTEX(); 
    if (portOpen) { 
        if (set) { 
            EscapeCommFunction(Win_Handle, SETDTR); 
        } 
        else { 
            EscapeCommFunction(Win_Handle, CLRDTR); 
        } 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn void Win_QextSerialPort::setRts(bool set) 
Sets RTS line to the requested state (high by default).  This function will have no effect if 
the port associated with the class is not currently open. 
*/ 
void Win_QextSerialPort::setRts(bool set) { 
    LOCK_MUTEX(); 
    if (portOpen) { 
        if (set) { 
            EscapeCommFunction(Win_Handle, SETRTS); 
        } 
        else { 
            EscapeCommFunction(Win_Handle, CLRRTS); 
        } 
    } 
    UNLOCK_MUTEX(); 
} 
 
/*! 
\fn ulong Win_QextSerialPort::lineStatus(void) 
returns the line status as stored by the port function.  This function will retrieve the states 
of the following lines: DCD, CTS, DSR, and RI.  On POSIX systems, the following additional lines 
can be monitored: DTR, RTS, Secondary TXD, and Secondary RXD.  The value returned is an unsigned 
long with specific bits indicating which lines are high.  The following constants should be used 
to examine the states of individual lines: 
 
\verbatim 
Mask        Line 
------      ---- 
LS_CTS      CTS 
LS_DSR      DSR 
LS_DCD      DCD 
LS_RI       RI 
\endverbatim 
 
This function will return 0 if the port associated with the class is not currently open. 
*/ 
ulong Win_QextSerialPort::lineStatus(void) { 
    unsigned long Status=0, Temp=0; 
    LOCK_MUTEX(); 
    if (portOpen) { 
        GetCommModemStatus(Win_Handle, &Temp); 
        if (Temp&MS_CTS_ON) { 
            Status|=LS_CTS; 
        } 
        if (Temp&MS_DSR_ON) { 
            Status|=LS_DSR; 
        } 
        if (Temp&MS_RING_ON) { 
            Status|=LS_RI; 
        } 
        if (Temp&MS_RLSD_ON) { 
            Status|=LS_DCD; 
        } 
    } 
    UNLOCK_MUTEX(); 
    return Status; 
} 
 
/*! 
\fn void Win_QextSerialPort::setTimeout(ulong sec, ulong millisec); 
Sets the read and write timeouts for the port to sec seconds and millisec milliseconds. 
*/ 
void Win_QextSerialPort::setTimeout(ulong sec, ulong millisec) { 
    LOCK_MUTEX(); 
    Settings.Timeout_Sec=sec; 
    Settings.Timeout_Millisec=millisec; 
    if(portOpen) { 
        Win_CommTimeouts.ReadIntervalTimeout = sec*1000+millisec; 
        Win_CommTimeouts.ReadTotalTimeoutMultiplier = sec*1000+millisec; 
        Win_CommTimeouts.ReadTotalTimeoutConstant = 0; 
        Win_CommTimeouts.WriteTotalTimeoutMultiplier = sec*1000+millisec; 
        Win_CommTimeouts.WriteTotalTimeoutConstant = 0; 
        SetCommTimeouts(Win_Handle, &Win_CommTimeouts); 
    } 
    UNLOCK_MUTEX(); 
}