www.pudn.com > TurboPower.Async.rar > AxDevPg.pas
(***** BEGIN LICENSE BLOCK *****
* Version: MPL 1.1
*
* The contents of this file are subject to the Mozilla Public License Version
* 1.1 (the "License"); you may not use this file except in compliance with
* the License. You may obtain a copy of the License at
* http://www.mozilla.org/MPL/
*
* Software distributed under the License is distributed on an "AS IS" basis,
* WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License
* for the specific language governing rights and limitations under the
* License.
*
* The Original Code is TurboPower Async Professional
*
* The Initial Developer of the Original Code is
* TurboPower Software
*
* Portions created by the Initial Developer are Copyright (C) 1991-2002
* the Initial Developer. All Rights Reserved.
*
* Contributor(s):
*
* ***** END LICENSE BLOCK ***** *)
{******************************************************************}
{* AXDEVPG.PAS 1.13 *}
{******************************************************************}
{* AxDevPg.PAS - Device configuration property page editor *}
{******************************************************************}
{$I AXDEFINE.INC}
unit AxDevPg;
interface
uses SysUtils, Windows, Messages, Classes, Graphics, Controls, StdCtrls,
ExtCtrls, Forms, ComServ, ComObj, StdVcl, AxCtrls, Mask, Buttons, dialogs,
ComCtrls;
type
TApxDevicePage = class(TPropertyPage)
Label3: TLabel;
edtAnswerOnRing: TEdit;
UpDown3: TUpDown;
Label6: TLabel;
edtTapiRetryWait: TEdit;
UpDown2: TUpDown;
Label1: TLabel;
edtMaxAttempts: TEdit;
UpDown1: TUpDown;
btnConfigure: TButton;
btnSelectedDevice: TButton;
edtSelectedDevice: TEdit;
Label2: TLabel;
chkEnableVoice: TCheckBox;
rbTapi: TRadioButton;
pnlWinsock: TPanel;
rbtnWsClient: TRadioButton;
rbtnWsServer: TRadioButton;
Label5: TLabel;
edtWinsockPort: TEdit;
edtWinsockAddress: TEdit;
Label4: TLabel;
rbWinsock: TRadioButton;
btnLineSettings: TButton;
Label10: TLabel;
cbxComNumber: TComboBox;
chkPromptForPort: TCheckBox;
rbDirect: TRadioButton;
Label7: TLabel;
Bevel3: TBevel;
Label8: TLabel;
Bevel4: TBevel;
Label9: TLabel;
Bevel5: TBevel;
chkFilterTapiDevices: TCheckBox;
procedure btnLineSettingsClick(Sender: TObject);
procedure btnSelectedDeviceClick(Sender: TObject);
procedure edtWinsockAddressChange(Sender: TObject);
procedure rbtnWsServerClick(Sender: TObject);
procedure rbDirectClick(Sender: TObject);
procedure chkFilterTapiDevicesClick(Sender: TObject);
private
public
procedure UpdatePropertyPage; override;
procedure UpdateObject; override;
end;
const
Class_ApxDevicePage : TGUID = '{FCA5D372-5F47-4CA3-8D02-C3F29A541B6B}';
implementation
uses
AdPort, AxLineDg, AxTerm, AdSocket, AdSelCom;
{$R *.DFM}
(*var
{ direct - line settings }
Baud : Integer;
DataBits : Integer;
ComNumber : Integer;
HWFlowUseDTR : WordBool;
HWFlowUseRTS : WordBool;
HWFlowRequireDSR : WordBool;
HWFlowRequireCTS : WordBool;
Parity : TParity;
PromptForPort : WordBool;
StopBits : Integer;
SWFlowOptions : TSWFlowOptions;
XOffChar : Integer;
XOnChar : Integer; *)
{== TApxDevicePage =======================================================}
procedure TApxDevicePage.UpdatePropertyPage;
var
I : Integer;
begin
try
for I := 1 to 50 do begin
if IsPortAvailable(I) then
cbxComNumber.Items.Add(IntToStr(I));
end;
{ direct - line settings }
chkPromptForPort.Checked := OleObject.PromptForPort;
cbxComNumber.Text := IntToStr(OleObject.ComNumber);
{ Baud := OleObject.Baud;
ComNumber := OleObject.ComNumber;
DataBits := OleObject.Databits;
StopBits := OleObject.StopBits;
Parity := OleObject.Parity;
PromptForPort := OleObject.PromptForPort;
HWFlowUseDTR := OleObject.HWFlowUseDTR;
HWFlowUseRTS := OleObject.HWFlowUseRTS;
HWFlowRequireDSR := OleObject.HWFlowRequireDSR;
HWFlowRequireCTS := OleObject.HWFlowRequireCTS;
SWFlowOptions := OleObject.SWFlowOptions;
XOnChar := OleObject.XOnChar;
XOffChar := OleObject.XOffChar;}
{ winsock }
edtWinsockAddress.Text := OleObject.WinsockAddress;
edtWinsockPort.Text := OleObject.WinsockPort;
rbtnWsClient.Checked := OleObject.WinsockMode = wsClient;
rbtnWsServer.Checked := OleObject.WinsockMode = wsServer;
{ tapi }
chkEnableVoice.Checked := OleObject.EnableVoice;
chkFilterTapiDevices.Checked := OleObject.FilterTapiDevices;
edtSelectedDevice.Text := OleObject.SelectedDevice;
UpDown1.Position := OleObject.MaxAttempts;
UpDown2.Position := OleObject.TapiRetryWait;
UpDown3.Position := OleObject.AnswerOnRing;
{ edtMaxAttempts.Text := OleObject.MaxAttempts;
edtTapiRetryWait.Text := OleObject.TapiRetryWait;
edtAnswerOnRing.Text := OleObject.AnswerOnRing;}
case OleObject.DeviceType of
ord(dtDirect) : rbDirect.Checked := True;
ord(dtWinsock) : rbWinsock.Checked := True;
ord(dtTapi) : rbTapi.Checked := True;
end;
for I := 0 to pred(ControlCount) do begin
Controls[I].Enabled := Controls[I].Tag = Ord(TApxDeviceType(OleObject.DeviceType)) + 1;
end;
rbDirect.Enabled := True;
rbWinsock.Enabled := True;
rbTapi.Enabled := True;
if (Ord(TApxDeviceType(OleObject.DeviceType)) + 1) <> 2 then begin
rbtnWsClient.Font.Color := clInactiveCaption;
rbtnWsServer.Font.Color := clInactiveCaption;
end else begin
rbtnWsClient.Font.Color := clWindowText;
rbtnWsServer.Font.Color := clWindowText;
end;
except
end;
end;
{ ----------------------------------------------------------------------- }
procedure TApxDevicePage.UpdateObject;
begin
try
if rbDirect.Checked then
OleObject.DeviceType := dtDirect
else if rbWinsock.Checked then
OleObject.DeviceType := dtWinsock
else
OleObject.DeviceType := dtTapi;
{ direct - line settings }
OleObject.PromptForPort := chkPromptForPort.Checked;
OleObject.ComNumber := StrToIntDef(cbxComNumber.Text, 0);
(*OleObject.Baud := Baud;
OleObject.ComNumber := ComNumber;
OleObject.Databits := DataBits;
OleObject.StopBits := StopBits;
OleObject.Parity := Parity;
OleObject.PromptForPort := PromptForPort;
OleObject.HWFlowUseDTR := HWFlowUseDTR ;
OleObject.HWFlowUseRTS := HWFlowUseRTS;
OleObject.HWFlowRequireDSR := HWFlowRequireDSR;
OleObject.HWFlowRequireCTS := HWFlowRequireCTS;
OleObject.SWFlowOptions := SWFlowOptions;
OleObject.XOnChar := XOnChar;
OleObject.XOffChar := XOffChar;*)
{ tapi }
OleObject.EnableVoice := chkEnableVoice.Checked;
OleObject.FilterTapiDevices := chkFilterTapiDevices.Checked;
OleObject.MaxAttempts := StrToIntDef(edtMaxAttempts.Text, 3);
OleObject.TapiRetryWait := StrToIntDef(edtTapiRetryWait.Text, 60);
OleObject.AnswerOnRing := StrToIntDef(edtAnswerOnRing.Text, 2);
OleObject.SelectedDevice := edtSelectedDevice.Text;
{ winsock }
if rbtnWsClient.Checked then
OleObject.WinsockMode := wsClient
else
OleObject.WinsockMode := wsServer;
OleObject.WinsockAddress := edtWinsockAddress.Text;
OleObject.WinsockPort := edtWinsockPort.Text;
except
end;
end;
{ ----------------------------------------------------------------------- }
procedure TApxDevicePage.btnLineSettingsClick(Sender: TObject);
var
LineDlg : TApxLineDlg;
begin
try
LineDlg := TApxLineDlg.Create(Self);
try
LineDlg.Baud := OleObject.Baud;
LineDlg.ComNumber := OleObject.ComNumber;
LineDlg.Databits := OleObject.DataBits;
LineDlg.StopBits := OleObject.StopBits;
LineDlg.Parity := OleObject.Parity;
LineDlg.PromptForPort := OleObject.PromptForPort;
LineDlg.HWFlowUseDTR := OleObject.HWFlowUseDTR ;
LineDlg.HWFlowUseRTS := OleObject.HWFlowUseRTS;
LineDlg.HWFlowRequireDSR := OleObject.HWFlowRequireDSR;
LineDlg.HWFlowRequireCTS := OleObject.HWFlowRequireCTS;
LineDlg.SWFlowOptions := OleObject.SWFlowOptions;
LineDlg.XOnChar := OleObject.XOnChar;
LineDlg.XOffChar := OleObject.XOffChar;
if (LineDlg.ShowModal = mrOk) then begin
OleObject.Baud := LineDlg.Baud;
OleObject.ComNumber := LineDlg.ComNumber;
OleObject.Databits := LineDlg.DataBits;
OleObject.StopBits := LineDlg.StopBits;
OleObject.Parity := LineDlg.Parity;
OleObject.PromptForPort := LineDlg.PromptForPort;
OleObject.HWFlowUseDTR := LineDlg.HWFlowUseDTR ;
OleObject.HWFlowUseRTS := LineDlg.HWFlowUseRTS;
OleObject.HWFlowRequireDSR := LineDlg.HWFlowRequireDSR;
OleObject.HWFlowRequireCTS := LineDlg.HWFlowRequireCTS;
OleObject.SWFlowOptions := LineDlg.SWFlowOptions;
OleObject.XOnChar := LineDlg.XOnChar;
OleObject.XOffChar := LineDlg.XOffChar;
Modified;
end;
finally
LineDlg.Free;
end;
except
end;
end;
{ ----------------------------------------------------------------------- }
procedure TApxDevicePage.btnSelectedDeviceClick(Sender: TObject);
begin
try
if OleObject.TapiSelectDevice then begin
edtSelectedDevice.Text := OleObject.SelectedDevice;
btnConfigure.Enabled := True;
Modified;
end;
except
end;
end;
{ ----------------------------------------------------------------------- }
procedure TApxDevicePage.edtWinsockAddressChange(Sender: TObject);
begin
Modified;
end;
procedure TApxDevicePage.rbtnWsServerClick(Sender: TObject);
begin
Modified;
end;
procedure TApxDevicePage.rbDirectClick(Sender: TObject);
var
I : Integer;
begin
for I := 0 to pred(ControlCount) do begin
Controls[I].Enabled := Controls[I].Tag = TRadioButton(Sender).Tag;
end;
rbDirect.Enabled := True;
rbWinsock.Enabled := True;
rbTapi.Enabled := True;
if TRadioButton(Sender).Tag <> 2 then begin
rbtnWsClient.Font.Color := clInactiveCaption;
rbtnWsServer.Font.Color := clInactiveCaption;
end else begin
rbtnWsClient.Font.Color := clWindowText;
rbtnWsServer.Font.Color := clWindowText;
end;
Modified;
end;
procedure TApxDevicePage.chkFilterTapiDevicesClick(Sender: TObject);
begin
OleObject.FilterTapiDevices := chkFilterTapiDevices.Checked;
end;
initialization
TActiveXPropertyPageFactory.Create(
ComServer,
TApxDevicePage,
Class_ApxDevicePage);