function [PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus
%IDX_BUS Defines constants for named column indices to bus matrix.
% [PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
% VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus
%
% Some examples of usage, after defining the constants using the line above,
% are:
%
% Pd = bus(4, PD); % get the real power demand at bus 4
% bus(:, VMIN) = 0.95; % set the min voltage magnitude to 0.95 at all buses
%
% The index, name and meaning of each column of the bus matrix is given
% below:
%
% columns 1-13 must be included in input matrix (in case file)
% 1 BUS_I bus number (1 to 29997)
% 2 BUS_TYPE bus type (1 = PQ, 2 = PV, 3 = ref, 4 = isolated)
% 3 PD Pd, real power demand (MW)
% 4 QD Qd, reactive power demand (MVAr)
% 5 GS Gs, shunt conductance (MW at V = 1.0 p.u.)
% 6 BS Bs, shunt susceptance (MVAr at V = 1.0 p.u.)
% 7 BUS_AREA area number, 1-100
% 8 VM Vm, voltage magnitude (p.u.)
% 9 VA Va, voltage angle (degrees)
% 10 BASE_KV baseKV, base voltage (kV)
% 11 ZONE zone, loss zone (1-999)
% 12 VMAX maxVm, maximum voltage magnitude (p.u.)
% 13 VMIN minVm, minimum voltage magnitude (p.u.)
%
% columns 14-17 are added to matrix after OPF solution
% they are typically not present in the input matrix
% (assume OPF objective function has units, u)
% 14 LAM_P Lagrange multiplier on real power mismatch (u/MW)
% 15 LAM_Q Lagrange multiplier on reactive power mismatch (u/MVAr)
% 16 MU_VMAX Kuhn-Tucker multiplier on upper voltage limit (u/p.u.)
% 17 MU_VMIN Kuhn-Tucker multiplier on lower voltage limit (u/p.u.)
%
% additional constants, used to assign/compare values in the BUS_TYPE column
% 1 PQ PQ bus
% 2 PV PV bus
% 3 REF reference bus
% 4 NONE isolated bus
% MATPOWER
% $Id: idx_bus.m,v 1.5 2004/12/15 22:46:28 ray Exp $
% by Ray Zimmerman, PSERC Cornell
% Copyright (c) 1996-2004 by Power System Engineering Research Center (PSERC)
% See http://www.pserc.cornell.edu/matpower/ for more info.
%% define bus types
PQ = 1;
PV = 2;
REF = 3;
NONE = 4;
%% define the indices
BUS_I = 1; %% bus number (1 to 29997)
BUS_TYPE = 2; %% bus type (1 - PQ bus, 2 - PV bus, 3 - reference bus, 4 - isolated bus)
PD = 3; %% Pd, real power demand (MW)
QD = 4; %% Qd, reactive power demand (MVAr)
GS = 5; %% Gs, shunt conductance (MW at V = 1.0 p.u.)
BS = 6; %% Bs, shunt susceptance (MVAr at V = 1.0 p.u.)
BUS_AREA = 7; %% area number, 1-100
VM = 8; %% Vm, voltage magnitude (p.u.)
VA = 9; %% Va, voltage angle (degrees)
BASE_KV = 10; %% baseKV, base voltage (kV)
ZONE = 11; %% zone, loss zone (1-999)
VMAX = 12; %% maxVm, maximum voltage magnitude (p.u.) (not in PTI format)
VMIN = 13; %% minVm, minimum voltage magnitude (p.u.) (not in PTI format)
%% included in opf solution, not necessarily in input
%% assume objective function has units, u
LAM_P = 14; %% Lagrange multiplier on real power mismatch (u/MW)
LAM_Q = 15; %% Lagrange multiplier on reactive power mismatch (u/MVAr)
MU_VMAX = 16; %% Kuhn-Tucker multiplier on upper voltage limit (u/p.u.)
MU_VMIN = 17; %% Kuhn-Tucker multiplier on lower voltage limit (u/p.u.)